The Art and Science of Psychrometrics

Jan 17, 2019Psychrometrics

Overview

I recently hosted an ASHRAE-sponsored webinar that discussed the
basics of psychrometrics and also included a demo of the ASHRAE
Psychrometric Chart iPad app
(which we designed). I was amazed that
almost 900 people registered for this webinar. This tells me that there
is keen interest in understanding psychrometrics and also finding ways
to more easily perform psychrometric calculations.

image

The following are links to both the webinar recording and a PDF of the PowerPoint slide deck:

  • Click here to view a recording of the webinar.
  • Click here to download a PDF of the PowerPoint slide deck.

This webinar included an overview of the science behind psychrometrics. Then, I
demo’d the app by creating sample HVAC processes. This webinar
could have easily gone on for two hours, but I was limited to one.
I will split this topic into 2 separate blog postings. This month’s posting will
talk about the basics of psychrometrics. A follow-up blog posting will
show 10 example HVAC processes using the psych chart app.

Importance of Psychrometrics

The
study and understanding of psychrometrics is so important for helping engineers to
design HVAC systems for all types of applications and situations including:

1.
It’s vital for human comfort since it’s difficult to work when the conditions are too
humid or too dry. The following slide displays the comfort zone for humans:

image

2. HVAC
systems designed for controlling the environment (temperature, humidity and
pollutants) within a museum, a library, or any type of archival facility is much more complex than the system
designed simply for maintaining human comfort. This system is designed to
control the environment for the preservation of highly valuable artifacts or
works of art. These HVAC systems must be operational 24/7 and often
require redundancy.

3.
Hospital ORs are kept so cold that there is always risk of condensation
from
the ceiling since the temperature often goes below the dew point of
ambient conditions (it’s called “raining in the OR”). Therefore, using
psychrometrics, it’s possible to determine the proper humidity ratio of the
air so as to eliminate condensation.

4. Many
industrial and manufacturing companies use chilled water to remove heat from
various manufacturing processes. As the air or process is cooled below the
ambient dew point, condensation can occur. Desiccant dehumidifiers can
eliminate this condensation. This results in a higher quality part and reduced
cycle time, allowing manufactured parts to be produced faster.

Is it Art or is it Science?

If you take the equations from the ASHRAE Handbook of Fundamentals seen below and
create a visual representation of those equations, it becomes a powerful tool for HVAC design.

image

You create this visually appealing chart that
allows you to plot simple and complex HVAC processes and actually visualize
them. Even those outside the
industry can begin to understand what the ratios of air to water mean and how
HVAC systems alter those ratios for the benefit of human comfort.

image

Definition of Psychrometrics

A psychrometric chart is a graph of the thermodynamic
parameters of moist air at a constant elevation or barometric pressure. The genius
behind this chart is that it allows HVAC professionals to visualize all types
of HVAC processes for cooling, heating, humidification, dehumidification and
much more.

Here’s
a chart at 0 feet elevation:

image

Here’s
a chart at 12,000 feet elevation. It looks a bit different than the 0 elevation
chart:

image

Before
psychrometric software for desktop or mobile, most engineers had to resort to using the
0 elevation chart even if they were designing a building in, say, Denver
which is 5000 ft
elevation. This produces inaccurate results because the density of air is so
different between 0 and 5000 feet. As you can see, the elevation change drastically changes the
shape of the graph.

The Components of the Psychrometric Chart

The following is a list of the components that make up a psychrometric chart:

image

Dry bulb temperature: The
temperature of air as registered by an ordinary thermometer

Absolute humidity or moisture
content:
The
weight of water vapor in grains or pounds of moisture per pound of dry air or grams of
water vapor per kg of air, i.e. g/kg. It is also known as moisture content or humidity
ratio.

Wet bulb temperature: The
temperature registered by a thermometer whose bulb is covered by a wetted wick and exposed to a
current of rapidly moving air (sling psychrometer)

Enthalpy: A
thermal property indicating the quantity of heat in the air above an arbitrary datum, in Btu per pound of dry air. The
datum for dry air is 0 deg F
and, for the moisture content
32 deg F water.

Specific volume: The
cubic feet of the mixture per pound of dry air or cubic meter of the mixture per kg of dry air represented in
m3/kg. It is the reciprocal of density. (1 over the density)

Relative humidity: RH is
an expression of the moisture content of a given atmosphere as a percentage of the saturation humidity
at the same temperature. Most everyone uses this # to communicate how humid it
is out: 50% humidity.

Dew point temperature: The
temperature at which condensation of moisture begins when the air is cooled. The best example of
this is a cold glass of water. If the temp. of the water is less than the dewpoint of
the ambient conditions, then you will see condensation on the outside of the
glass.

SHR protractor: Allows the user to draw
the SHR line which is discussed later.

Other Psychrometric Terms

image

Saturation curve: This is where the air
is 100% saturated no matter what the DB and WB
temperatures are. Along this curve, the DB, WB, and DP are all the same at any
1 point.

ADP: Apparatus dew point (ADP) is the coil
surface dew point temperature required to accomplish a cooling/dehumidifying
process. As you can see from this simple psych drawing, the air entering the
coil is cooled to slightly less than 100% saturation. If you want to extract
water out of the air (dehumidify), then you need to approach the ADP which does
exactly that.

Bypass factor: Some
of the air flowing through the coil impinges on the water tubes or the fins and
is cooled to the ADP. Other air passes through unchanged.

SHR: The ratio of space sensible cooling
to total cooling is useful for plotting the slope
of the path that supply air travels after
introduction into the space.

Adiabatic cooling: This is also called
evaporative cooling or constant-enthalpy
cooling. Adiabatic
cooling is
the process of reducing heat through a change in air pressure caused by volume
expansion. It’s also called free
cooling since the sensible heat is being converted to latent heat without the
help of mechanical DX cooling.

Simple Psychrometric Processes

image

Sensible heating/cooling involves the increase or decrease in the
temperature of air without changing its humidity ratio. Example: passing moist
air over a room space heater.

Humidification/dehumidification involves the increase or decrease in the
humidity ratio of air without changing its dry bulb temperature.

Heating and humidifying involves the
simultaneous increase in both the dry bulb temperature and humidity ratio of the air.

Cooling and dehumidifying involves
the removal of water from the air as the air temperature falls below the dew-point temperature.

Evaporative
cooling
involves
the cooling of air without heat loss or gain. Sensible heat lost by the air is
converted to latent heat in the added water vapor. Also called “Free cooling”.

Chemical dehumidification or adiabatic dehumidification is
accomplished by passing air through a chemical absorbent like silica gel. Some of the moisture is removed and the latent
heat of evaporation is released. There will be an increase in sensible heat
content and along the enthalpy line.

Complex Processes

image

Complex psychrometric process include a combination of the
simple processes discussed above. I will touch upon these complex processes in next month’s blog that will include up to 10 examples of complex psychrometric processes.

Click the following image to download the app:

image

Stay tuned for next month where I will describe 10 psychrometric use cases ranging from simple cooling to complex combo indirect/direct dehumidification and cooling.

ASHRAE Building Energy Quotient (Building EQ) Website

ASHRAE Building Energy Quotient (Building EQ) Website

ASHRAE’s Building EQ Portal provides a quick energy analysis that benchmarks a building’s energy performance. Building EQ assists in the preparation of an ASHRAE Level 1 Energy Audit to identify means to improve a building’s energy performance including low-cost, no-cost energy efficiency measures and an Indoor Environmental Quality (IEQ) survey with recorded measurements to provide additional information to assess a building’s performance.